Data Center
-
IDC Rack (Internet Data Center Rack)
Ntsiab nta & Specifications:
Loj: txheem dav: 19 nti (482.6 mm) Qhov siab: Rack Unit 47U Qhov tob: 1100mm
Txhawb kev cai loj raws li koj xav tau.
Load Capacity: Rated nyob rau hauv kilograms los yog phaus. Nws yog ib qho tseem ceeb kom ntseeg tau tias lub txee tuaj yeem txhawb nqa tag nrho qhov hnyav ntawm txhua yam khoom siv.
Cov Khoom Siv: Ua los ntawm cov khoom hnyav, txias-kuav los tiag steel rau lub zog thiab kav ntev.
Perforation: Pem hauv ntej thiab nram qab qhov rooj feem ntau perforated (meshed) kom tso cai rau kev pom huab cua.
Compatibility: Tsim los tuav tus qauv 19-nti khib-mount khoom.
Cable Management: Ob lub input cables nrog CEE 63A plugs, cable tswj tuav / ntiv tes ducts los npaj thiab coj kev network thiab fais fab cables.
Kev Ua Kom Zoo Txias: Cov qhov rooj perforated thiab cov vaj huam sib luag pab txhawb cov cua kom zoo, tso cai rau cov cua txias los ntawm cov ntaub ntawv chaw txias kom ntws los ntawm cov khoom siv thiab tso cua kub kom zoo, tiv thaiv kev kub dhau.
Vertical PDU (Power Distribution Unit): Ob 36 qhov chaw nres nkoj C39 ntse PDUs mounted rau ntawm txoj kab ntsug kom muab cov hluav taws xob hluav taws xob ze rau cov khoom siv.
Daim Ntawv Thov: IDC Txiaj Ntsig, tseem hu ua "Server Rack" lossis "Network Cabinet", yog tus qauv tsim, kaw cov qauv tsim los kom ruaj ntseg hauv tsev thiab teeb tsa cov cuab yeej IT tseem ceeb hauv Data Center lossis chav server nplooj siab. "IDC" sawv cev rau "Internet Data Center".
-
Miner khib nrog 40 Ports C19 PDU
Specifications:
1. Txee Loj (W * H * D): 1020 * 2280 * 560mm
2. PDU Loj (W * H * D): 120 * 2280 * 120mm
Input Voltage: peb theem 346 ~ 480V
Tawm tswv yim tam sim no: 3 * 250A
Output voltage: ib theem 200 ~ 277V
Qhov hluav taws xob: 40 qhov chaw nres nkoj ntawm C19 Sockets teeb tsa hauv peb ntu
Txhua qhov chaw nres nkoj muaj 1P 20A Circuit Court breake
Peb cov mining rig nta ib ntsug-mounted C19 PDU nyob rau sab rau ib tug sleek, txuag chaw thiab kev layout.
Ntxuav, teeb tsa thiab ua kom zoo rau kev ua haujlwm siab tshaj plaws.
-
2500A Sab Nraud Fais Fab Fais Txias Txias
Switchboard Specification:
1. Voltage: 415V / 240 VAC
2. Tam sim no: 2500A, 3 Phase, 50/60 Hz
3. SCCR: 65 TSI
4. Cov khoom siv txee: SGCC
5. Enclosure: NEMA 3R sab nraum zoov
6. Main MCCB: Noark 3P/2500A 1PCS
7. MCCB: Noark 3P/250A 10PCS & 3P/125A 1PCS
8. 3 Phase muti-function fais fab ntsuas
-
HPC 36 PORTS C39 SMART PDU
PDU specifications
1.Input voltage: 346-415VAC
2. Cov tswv yim tam sim no: 3 x 60A
3. Cov zis hluav taws xob: 200 ~ 240VAC
4. Cov qhov hluav taws xob: 36 qhov chaw nres nkoj ntawm C39 qhov (sockets) nrog rau tus kheej-locking feature Socket tau tshaj C13 thiab C19
5. Cov qhov hluav taws xob tau teeb tsa nyob rau hauv alternating theem sequence nyob rau hauv dub, liab, xiav xim
6. Kev tiv thaiv: 12 pcs ntawm 1P 20A UL489 hydraulic magnetic Circuit Court breakers Ib tug breaker txhua peb qhov hluav taws xob
7. Chaw taws teeb saib PDU input tam sim no, voltage, hwj chim, KWH
8. Cov chaw taws teeb saib xyuas txhua qhov chaw tso zis tam sim no, qhov hluav taws xob, lub zog, KWH
9. Ntse Meter nrog Ethernet / RS485 interface, txhawb HTTP / SNMP / SSH2 / MODBUS
10. Onboard LCD zaub nrog cov zaub mov tswj thiab saib xyuas hauv zos
11. Kev khiav hauj lwm ib puag ncig kub 0 ~ 60C
12. UL / cUL Cov Ntawv Teev Npe thiab Ntawv Pov Thawj (ETL Mark)
13. Lub input davhlau ya nyob twg muaj 5 X 6 AWG kab 3 meter
-
HPC 24 PORTS C39 SMART PDU
PDU Specifications:
1. Input voltage: 346-415V
2. Cov tswv yim tam sim no: 3 * 125A
3. Cov zis hluav taws xob: 200-240V
4. Cov qhov hluav taws xob: 24 qhov chaw nres nkoj ntawm C39 qhov (sockets) nrog rau tus kheej-locking feature Socket tau tshaj C13 thiab C19
5. Kev tiv thaiv: 24pcs ntawm 1P20A UL489 Circuit Court breakers Ib qho tawg rau txhua qhov hluav taws xob
7. Cov chaw taws teeb saib xyuas PDU input thiab txhua qhov chaw nres nkoj tam sim no, qhov hluav taws xob, lub zog, KWH
8. Cov chaw taws teeb saib xyuas txhua qhov chaw tso zis tam sim no, qhov hluav taws xob, lub zog, KWH
9. Ntse Meter nrog Ethernet / RS485 interface, txhawb HTTP / SNMP / SSH2 / MODBUS
10. UL/cUL Sau thiab Certified